Voice Synthesiser VS1
The VS1 Voice Synthesiser system comprises of a Controller Interface Module (fitted in the lift
controller) which has integral control with the TC3 Digital Indicator range and a voice synthesiser
fitted on the lift car or landings.
The Controller Interface Module will support up to 64 Digital Indicators and a Voice Synthesiser
Unit. The Voice Synthesiser Unit can announce up to 32 floor references (which are site
programmable within the standard voice library constraints), direction status, door status, and 3
messages.
 Voice Synthesiser VSSA
The VSSA voice synthesiser system is a stand alone unit designed to give voice announcements
regarding the lift position, direction, door operation and service status.
The voice synthesiser unit can announce up to 63 floor references (which are factory programmed
within the standard voice library constraints), direction status, door status, and 3 messages.
The audio output is via a 8 ohm speaker at 1 watt. It uses latest developments of circuit
integration together with surface mount manufacturing techniques to give a unit footprint of
140mm x 90mm and 30mm tall.
Product Codes
Notice: iconv() [function.iconv]: Detected an illegal character in input string in F:\percy\Mcangus\Clients\lester01\wwwroot\Excel\reader.php on line 796
|
|
VS1 (TC3) Voice Unit |
VS1 |
£125.00 |
TC3 Interface |
TC3 I/FACE |
£130.00 |
Stand Alone Voice Unit |
VSSA |
£195.00 |
Special Message Voice Unit |
VU2 |
£245.00 |
Speaker |
SPEAK |
£7.50 |
|
|
|
|
|
Features
Voice Synthesiser Unit Features
• Intelligent selection of 32 floor
announcements, direction status, door
status and 3 message announcements
• Uses latest developments of circuit
integration together with surface mount
manufacturing techniques to give a unit
footprint of 70mm x 65mm and 40mm
deep
• Utilises CAN communications to
reduce site wiring and ease
installation (2 wires for power and 2
wires for communications)
• The output audio is via a 8 ohm speaker
at 1 watt
Controller Interface Unit Features
Incorporates an LCD to monitor and
program the Digital Indicator and Voice
Synthesiser operation
Floor Identities are site programmable
into NVRAM with no special equipment
required provided the floor
announcements are within the standard
announcement library
Inputs are opto-isolated for 24vDC
operation and include :-
Binary position inputs PA, PB, PC, PD, PE, PF for up to 32 floors.
SX input for Speech Position Data
Announcement Control
IU, ID,HL inputs for Hall Lantern
Announcement Control
DC, DO inputs for door open and close
announcements
OS, OL, FC for messages
Note: A decimal to binary encoder unit is
available as an optional chargeable extra
to help controller position data interfacing
|
|